Products/acoustic imaging camera

VS138X Handheld acoustic imaging camera

Channel 2-100 kHz with acoustic imaging to support leakage and partial discharge analysis.

VS138X Handheld acoustic imaging camera
01

138 Channel Acoustic Array

Acoustic location is superseded to visible light images using 138 MEMS microphones to collect sound signals.
02

Wideband Filter

Adjust detection bands within 2-100 kHz to help distinguish target acoustic sources from background noise.
03

Leak analysis

Support for leak detection and loss estimates could form the basis for the maintenance ranking, for example, in combination with on-site pressure.
04

partial discharge analysis

Provides PRPD analysis and cutting-edge, along-line, suspended electricity and noise classification information to assist subsequent diagnosis.
Designed for testing

VS138X Product and Test Capacity

VS138X is a handheld acoustic imaging camera for gas leaks and electrical partial discharge inspections.138 MEMS microphones collected 2-100 kHz sound signals, which were superseded with 13 million pixels visible images, to help operators locate abnormal sources from live images.A body less than 1 kg is suitable for mobile patrols and multiple inspections.

The built-in laser range allows for the recording of target distances, and leakage loss estimates, PRPD classification and spectrum analysis are used to further understand detection signals.The instrument supports off-line analysis and reporting, which is accompanied by photographic, video, voice and text labelling, and keeps the location of the equipment, detection conditions and anomalies in the same field record.

  • check_circle138 Channel Acoustic Array
  • check_circleWideband Filter
  • check_circleLeak analysis
  • check_circlepartial discharge analysis
VS138X Handheld acoustic imaging camera
Core functions

Designed for physical testing

The key capabilities that affect the efficiency of on-site testing are centralized in a testing platform.

01

138 Channel Acoustic Array

Acoustic location is superseded to visible light images using 138 MEMS microphones to collect sound signals.

02

Wideband Filter

Adjust detection bands within 2-100 kHz to help distinguish target acoustic sources from background noise.

03

Leak analysis

Support for leak detection and loss estimates could form the basis for the maintenance ranking, for example, in combination with on-site pressure.

04

partial discharge analysis

Provides PRPD analysis and cutting-edge, along-line, suspended electricity and noise classification information to assist subsequent diagnosis.

05

Laser ranging

Inline 0.1-20 m laser ranging to record target distance and assist with detection settings.

06

Review and reporting on board

Support for acoustic data analysis, photo video playback and processing of test reports, offline.

07

Multi-form record

Text, voice, images and labels can be added to facilitate association equipment, location and unusual records.

08

Wireless and power supply

Double-frequency Wi-Fi, Bluetooth and USB are available to support Type-C PD and base charging.

Typical application

Compressed air leak

(c) Positioning the ultrasound sources in the interface, hoses, valves and pipes and recording the state of maintenance before and after maintenance.

Electrical partial discharge

The acoustic positioning of switch equipment, insulation components and connection locations was performed, and PRPD information was reviewed.

Petrochemical and process industries

Checking the leaking sources of valves, Frank and accessable pipes, and identifying problems in conjunction with field work.

Mechanical acoustic screening

The preservation of audio records is used for subsequent analysis through the abnormal acoustic area of the audio superheavy positioning device.

Test Process

Full detection process from entry to judgement

01

Confirm target and distance.

02

Select frequency band and scan

03

Position and review the sound sources

04

Save sound and labels

05

Post-maintenance review

Technical parameters

Microphone Array138 MEMS
Audio frequency range2–100 kHz
Audio test distance0.3 - 150 m, Acoustic Sources and Environmental Impact
Acoustic Frame Rate30 fps
Microphone sensitivity−26 ± 1 dBFS
Scan Precision≤1°
Position Precision Conditions≤1 cm @ 1 m、40 kHz
Leak Checking Reference≤0.05 L/min @ 10 m、1.2 bar
Laser range0.1–20 m
Visible Photopixels13 million pixels
Visible Optical field corner72° ± 3°
Visible light focal length3.9 mm, Focus
DisplayLCD
Show Resolution1280 × 720
Number Zoom1× / 2× / 4× / 8×
Photo Resolution3840 × 2160 / 1920 × 1080
Video1920 × 1080,30 fps
Memory Card128 GB microSD
OrganisationText / Voice / Image / Label
Wireless connectionWi-Fi 2.4 / 5 GHz;Bluetooth 4.2
Charge MethodType-C PD / Base
Battery≥4500 mAh / 7.2 V
Dimensions333 × 152 × 115 mm
Protection level≥IP54
Working temperature-20 to 55° C
Storage temperature-40 to 85° C
Relative humidity10-95%, no condensation.
tripod interfaceUNC 1/4-20
Whole weightLess than 1 kg

This model is acoustic and visible light configuration and does not contain infrared thermal imaging parameters for VS138XH.The detection distance, leak sensitivity and location accuracy are relevant to the test conditions and the loss estimates are based on input consistent with the field condition.