Products/acoustic imaging camera

VS130EP Infrared acoustic imaging camera

132 Channel Acoustic Array, 640 x 512 Thermal Images and 10 inches full of high screens with parameters corresponding to VS130EP PDF.

VS130EP Infrared acoustic imaging camera
01

Acoustic and infrared integration

Sound positioning is associated with 640 x 512 thermal imaging, with separate observation equipment acoustic and temperature distribution.
02

132 Channel Array

132 MEMS microphones covering 2-100 kHz, supporting visualization of the distribution of acoustic sources.
03

Reconciliation of field parameters

Modifiable bands, thresholds, and dynamic ranges, and setting up noise reduction areas to support the screening of target signals.
04

Steady and transient analysis

Conducts acoustic examinations in conjunction with scene settings using a continuous or intermittent sound selection algorithm.
Designed for testing

VS130EP Product and Test Capacity

VS130EP uses the acoustic combination of infrared thermal imaging, 132 MEMS microphones covering the 2-100 kHz acoustic segment, 640 x 512 to record the temperature distribution of the infrared oxidation detectors.10 inches full-scale touch screens are aligned with visible images to allow cross-observation of acoustic sources and heat anomalies at the site.

Equipment supports steady and transient algorithms, frequency band and threshold adjustments, custom noise reduction areas, leakage rate displays and PRPD analysis.Photographs, videos, replays, labels and on-board reporting functions can document detection conditions and findings.Infrared modules provide painting and independent thermal displays and display the highest, lowest and central point temperature;This page parameter is organized according to the VS130EP PDF.

  • check_circleAcoustic and infrared integration
  • check_circle132 Channel Array
  • check_circleReconciliation of field parameters
  • check_circleSteady and transient analysis
VS130EP Infrared acoustic imaging camera
Core functions

Designed for physical testing

The key capabilities that affect the efficiency of on-site testing are centralized in a testing platform.

01

Acoustic and infrared integration

Sound positioning is associated with 640 x 512 thermal imaging, with separate observation equipment acoustic and temperature distribution.

02

132 Channel Array

132 MEMS microphones covering 2-100 kHz, supporting visualization of the distribution of acoustic sources.

03

Reconciliation of field parameters

Modifiable bands, thresholds, and dynamic ranges, and setting up noise reduction areas to support the screening of target signals.

04

Steady and transient analysis

Conducts acoustic examinations in conjunction with scene settings using a continuous or intermittent sound selection algorithm.

05

Leakage and discharge analysis

Support for real-time leakage rate displays and PRPD analysis to review test results in conjunction with field conditions.

06

Infrared Observation Tool

Provide painting, independent thermal images and maximum, lowest and central temperature displays.

07

Largescreen field operation

10 inches 1920 x 1080 ECT screen with hands attached to a fixed focal-point visible camera.

08

Records and aircraft reports.

Supporting the generation of photographs, videos, replays, labels and reports to facilitate the collation of inspection findings.

Typical application

Compressed air leak

(c) Positioning the ultrasound sources in the interface, hoses, valves and pipes and recording the state of maintenance before and after maintenance.

Electrical partial discharge

The acoustic positioning of switch equipment, insulation components and connection locations was performed, and PRPD information was reviewed.

Petrochemical and process industries

Checking the leaking sources of valves, Frank and accessable pipes, and identifying problems in conjunction with field work.

Mechanical acoustic screening

The preservation of audio records is used for subsequent analysis through the abnormal acoustic area of the audio superheavy positioning device.

Test Process

Full detection process from entry to judgement

01

Confirm target and distance.

02

Select frequency band and scan

03

Position and review the sound sources

04

Save sound and labels

05

Post-maintenance review

Technical parameters

Data matching modelVS130EP
StructureHands on, aluminum alloy.
Dimensions255 × 196 × 52 mm
Weight2.09 kg, with straps and cushions
Protection levelIP56
DisplayTen inches of electro-capacitive touch screen
Show Resolution1920 × 1080
acoustic imaging Frame Rate25 fps
Visible light camera12 million pixels, focus.
Visible Optical field corner60° × 40°
Microphone Array132 MEMS
Working frequency2–100 kHz
Scan Precision≤1°
AlgorithmSteady / transient
Signal reconciliationFrequency / Threshold / Dynamic Range / Noise Reduction Area
Analyzing functionReal time leakage / PRPD
Infrared detectorNon-refrigerant oxidation VOx
Infrared Resolution640 × 512
Infrared.15 mm
It's like space.12 μm
Infrared band8–14 μm
Temperature range-20 to 550°C
Temperature precision± 2° C or ± 2% of the read, to take greater value
Infrared FocusAutomatically focus, minimum focus distance 5 m
Infrared Frame Rate50 / 60 Hz
Thermal displayDraws an independent thermal image;Maximum / Minimum / Central Temperature
Storage128 GB
Data interfaceMemory Card / USB
Auxiliary lighting1 W
Battery5000 mAh / 11.1 V
Re-entry.4 hours
Working temperature-25 to 50° C
Storage temperature-20 to 40° C
Relative humidity10-92%, no condensation

Parameters are based on the corresponding VS130EP technical parameter PDF.The minimum infrared focal distance is 5 m, and the actual temperature range is checked when selecting;Temperature accuracy, continuity and detection are affected by conditions on the ground, with delivery configuration based on corresponding information.

Need help?

Contact industrial inspection expert.

Tell us about your application, and we'll help recommend the right product configuration.

Contact us. →